Product Details
Place of Origin: China
Brand Name: LENGE
Certification: ISO/CE
Model Number: LATM1440
Payment & Shipping Terms
Minimum Order Quantity: 1 SET
Price: Negotiate
Packaging Details: Wooden cases
Delivery Time: 15-20 Days
Payment Terms: T/T, L/C
Supply Ability: 50 Sets per Month
Material: |
SUS 304 |
Air Flow: |
0.45m/s ± 20% |
UV Light: |
Yes |
Seal: |
Seal System |
Leakage Rate: |
<0.5%/h |
Power: |
380 V / 50 Hz |
Material: |
SUS 304 |
Air Flow: |
0.45m/s ± 20% |
UV Light: |
Yes |
Seal: |
Seal System |
Leakage Rate: |
<0.5%/h |
Power: |
380 V / 50 Hz |
Stainless Steel VHP Sterilization Chamber With Three Levels Of Authority Management
Stainless Steel VHP Sterilization Chamber With Three Levels Of Authority Management
Item | Technical Specification |
Material | SUS304/316L Stainless Steel |
Application | Pharmaceuticals, Food & Beverage, Electronics |
Structure | Fully Enclosed |
Sterilization Time | <120 min. |
Vaporization Power | Clean Compressed Air |
Sterilization Efficacy | 6-log |
Sterilization Media | 30% Medical Grade H2O2 |
Maintenance Mode | Side Access/Up-Down Access |
Inlet Air Purification | H14 |
Cycling Mode | Direct Exhaust |
Validation Document | 4Q/FAT/SAT |
System Monitoring | Increase concentration |
Soft System | Display the current step, remaining time and working status of main parts, time setting, system parameter setting, alarm information, online data monitoring, manual and automatic switching, sterilization batch input, validation information, PDF report, formula management |
Vaporized Hydrogen Peroxide
The vaccine industry is generally used for delivery:
Chamber air tightness test:JG/T 382-2012“Pass box”( - 500 Pa pressure maintaining 20 min,≤ - 250 Pa)
HEPA leak detection: in situ scanning leak detection can be done for high efficiency of air supply and exhaust
Cleanliness: static class A
Operation Principle
Chamber air tightness test:JG/T 382-2012“Pass box”( - 500 Pa pressure maintaining 20 min,≤ - 250 Pa)
HEPA leak detection: in situ scanning leak detection can be done for high efficiency of air supply and exhaust
Cleanliness: static class A
Characteristic & Features
Sterilization process <120min. to realize multiple sterilization operations one day.
Emergency Stop.
Decomposition filter can effectively reduce the concentration of VHP remain Reduce the impact on environment and personnel.
Very low hydrogen peroxide consumption.
Engineering Drawing
Sterilization Process & Vaporizer Schematic Diagram
Serial NO. | Name |
1 | Evaporation system |
2 | Exhaust system |
3 | Air supply system |
4 | Exhaust duct |
5 | The sterilization chamber |
6 | Commodity shelf |
7 | Electric mounting bracket |