logo
Send Message
Wuxi Lenge Purification Equipments Co., Ltd.
products
products
Home > products > Clean Room Equipments > 1300x1200x2570 Closed Negative Pressure Weighing Room For Pharma

1300x1200x2570 Closed Negative Pressure Weighing Room For Pharma

Product Details

Place of Origin: China

Brand Name: LENGE

Certification: CE/SGS/ISO

Model Number: LWR 112-300200

Payment & Shipping Terms

Minimum Order Quantity: 1 SET

Price: Negotiate

Packaging Details: Wooden cases

Delivery Time: 15-20 Days

Payment Terms: T/T, L/C

Supply Ability: 100 Sets per Month

Get Best Price
Highlight:
Product Name:
Weighting Room
Material:
SUS 304/316L
Size:
1300x1200x2570mm
Wind Speed:
0.45m/s ± 20 %
Warranty:
1 Year
Controller:
HMI
Filtration:
G4 + F8 + H14
Cleanliness Class:
Same As The Background Area
Product Name:
Weighting Room
Material:
SUS 304/316L
Size:
1300x1200x2570mm
Wind Speed:
0.45m/s ± 20 %
Warranty:
1 Year
Controller:
HMI
Filtration:
G4 + F8 + H14
Cleanliness Class:
Same As The Background Area
1300x1200x2570 Closed Negative Pressure Weighing Room For Pharma

1300x1200x2570 Closed Negative Pressure Weighing Room For Pharma

Characteristics & Features: 

  • Cross contamination control through negative pressure environment option.

  • GMP modular design with minimized joints and seams.

  • All components meet or exceed applicable safety requirements.

 

Technical Specifications & Parameters: 

 

Material

SUS 304/316L stainless steel

Filter Module

Pre-filter, comport filter, HEPA filter

Core Part

Air Blower

Model No.

LWR 13-120060

LWR 34-150120

LWR 75-200200

LWR 112-300200

LWR 186-400250

Outer Size
W×D×H (mm)

1300×1200×2570

1600×1800×2570

2100×2800×2570

3100×2800×2570

4100×3300×2570

Inner Size
W'×D'×H' (mm)

1200×600×2000

1500×1200×2000

2000×2000×2000

3000×2000×2000

4000×2500×2000

Rated Air Velocity
(m/s)

0.45±20%

Cleanliness Class

Same as the background area

Power Supply

380V, 50Hz

Power (kW)

0.8

2

4

4

7.5

Note: The specifications listed in above table are only for customer’s reference. It is mostly designed and manufactured according to customer’s URS.
Containment System: 

  • Main Stream - The opening provides an airflow velocity of 0.45 m/s.

  • HEPA fan module provides laminar flow of particlefree air (measured at 0.3µm particles) to meet clean room requirements—99.995% efficient ULPA filters also available.

  • Filter Module

  • —— Pre filter -- Panel filter G4

  • —— Comfort filter -- Bag filter F8

  • —— HEPA filter -- Gel sealed mini-pleated HEPA filter H14

  • 380 V power supply

 

Product Outline Design:

称量

 

 

1300x1200x2570 Closed Negative Pressure Weighing Room For Pharma 11300x1200x2570 Closed Negative Pressure Weighing Room For Pharma 2

1300x1200x2570 Closed Negative Pressure Weighing Room For Pharma 3

Dispensing Booth also called negative pressure weighing chamber, is a kind of local air purification equipment specially used for weighing raw and auxiliary materials in pharmaceutical factories.

It provides a vertical single airflow, in which part of the airflow is circulated in the working area, and the other part of the airflow is filtered by a high-efficiency filter and then discharged from the equipment, so that the interior of the equipment can form a negative pressure relative to the outside to prevent dust from spreading and cross-contamination. And protect the safety of staff and the surrounding environment.

The weighing room is special local purification equipment used in places such as pharmaceuticals, microbial research, and scientific experiments.

It provides a vertical one-way airflow, part of the clean air circulates in the working area, and part of it is discharged to the nearby area so that the working area can generate negative pressure and prevent cross-contamination, which is used to ensure a high cleanliness environment of the working area.

Weighing and dispensing dust and reagents in the equipment can control the spillage and uplift of dust and reagents, prevent the inhalation hazards of dust and reagents to the human body, avoid cross-contamination of dust and reagents, and protect the safety of the external environment and indoor personnel.

The weighing operation area is protected by thousand class vertical laminar flow ISO 6 (NF, EN, ISO14644-1).